From

4,690₾

Get a Quote
Deye SUN-30K-G04 On-Grid Inverter
SKU
SUN-30K-G04
Brand
Deye
Datasheet (PDF)

Deye SUN-30K-G04 On-Grid Inverter

The Deye SUN-30K-G04 anchors medium commercial PV plants where 30 kW AC export is licensed and battery economics are evaluated separately from generation ROI.

Tech Specs

Deye SUN-30K-G04 On-Grid Inverter — Tech Specs
Parameter SUN-30K-G04 SUN-33K-G04 SUN-35K-G04 SUN-36K-G04
PV String Input Data
Max. PV Input Power(kW) 45 49.5 52.5 54
Max. PV Input Voltage(V) 1100
Start-up Voltage(V) 250
MPPT voltage range(V) 200-1000
Rated PV Input voltage(V) 600
Max. Input Short Circuit Current (A) 60+60
Max. Operating PV Input Current(A) 40+40
No. of MPP Trackers/No. of Strings per MPP Tracker 2/3+3
AC Output Side
Rated AC Output Active Power(kW) 30 33 35 36
Max. AC Output Apparent Power(kVA) 33 36.3 38.5 39.6
Rated AC output current (A) 45.5/43.5 50/47.8 53/50.7 54.5/52.2
Max. AC Output Current(A) 50/47.9 55/52.6 58.3/55.8 60/57.4
Rated output voltage/range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.60%
Euro Efficiency 98.10%
MPPT Efficiency >99%
Equipment Protection
DC Reverse Polarity Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
Insulation Impedance Detection Yes
DC Component Monitoring Yes
Arc Fault Circuit Interrupter (AFCI) Optional
Anti-islanding Protection Yes
Residual Current Detection Yes
Surge Protection Level TYPE II(DC),TYPE II(AC)
DC Switch Yes
Interface
Communication Interface RS485/RS232
Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0~100%
Permissible Altitude (m) 4000m
Noise (dB) ≤ 60
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC),OVC III(AC)
Cabinet Size (WxHxD mm) 330*572*206(Excluding connectors and brackets)
Weight [kg] 28.7
Warranty [year] 5 years
Type Of Cooling Intelligent air cooling
Grid Regulation IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Thirty kilowatts of continuous On-Grid capacity materially shifts monthly demand charges for warehouses and production halls—especially when load aligns with solar peak. The G04 platform stays in the On-Grid domain: no SOC management, no DC arc-flash protocols beyond PV open-circuit voltage.

Designers should coordinate AC breaker frames, surge protection, and labeling with the facility's main LV panel. Multiple MPPT trackers accommodate long combiner runs from distant roof sections. If export is capped below instantaneous production, configure gradient export limits to avoid utility disconnects.

Crossing into storage territory (>40 kWh or backup mandates) typically pivots to HV hybrid (SG01HP3) rather than bolting LV racks onto an On-Grid-only site. Treat this inverter as the generation engine; add storage as a deliberate second CAPEX line.

Ideal for

  • Medium warehouses and agro-processing with 30 kW connection tiers
  • EPC firms standardizing on Deye commercial On-Grid SKUs
  • Owners separating generation ROI from future storage phases

Technical FAQ

When does 30K On-Grid hit diminishing returns vs hybrid?
When outage cost exceeds storage CAPEX—hospitality, medical, cold chain—or when peak demand charges exceed 0.35 ₾/kWh energy savings alone.
Can I add batteries to this model?
Not natively. Plan a hybrid feeder or AC-coupled storage inverter for critical circuits.
Typical payback drivers?
Self-consumption rate, module $/W, installation quality, and tariff escalation—not nameplate kW alone.
EV fleet charging?
Daytime PV can feed 22 kW wallboxes; coordinate breaker sizing and dynamic load management with our charger lineup.
← Back to catalog: Inverters