From

2,545₾

Get a Quote
Deye SUN-5…15K-G06 On-Grid Inverter
SKU
SUN-5…15K-G06
Brand
Deye
Datasheet (PDF)

Deye SUN-5…15K-G06 On-Grid Inverter

The Deye SUN-5…15K-G06-EU is a three-phase On-Grid workhorse for larger homes, guesthouses, and light commercial roofs where balanced phase loading and dual MPPT flexibility matter more than storage.

Tech Specs

Deye SUN-5…15K-G06 On-Grid Inverter — Tech Specs
Parameter SUN-3K-G06P3-EU-BM2-P1 SUN-4K-G06P3-EU-BM2-P1 SUN-5K-G06P3-EU-BM2-P1 SUN-6K-G06P3-EU-BM2-P1 SUN-7K-G06P3-EU-BM2-P1 SUN-8K-G06P3-EU-BM2-P1 SUN-9K-G06P3-EU-BM2-P1 SUN-10K-G06P3-EU-BM2-P1 SUN-12K-G06P3-EU-BM2-P1 SUN-15K-G06P3-EU-BM2-P1
PV String Input Data
Max. PV Input Power (kW) 4.5 6 7.5 9 10.5 12 13.5 15 18 22.5
Max. PV Input Voltage (V) 1100
Start-up Voltage (V) 140
MPPT Voltage Range (V) 120-1000
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 20+20 20+20 20+20 20+20 20+20 20+20 20+20 20+20 20+20 20+26
Max. Input Short Circuit Current (A) 30+30 30+30 30+30 30+30 30+30 30+30 30+30 30+30 30+30 30+39
No. of MPP Trackers/No. of StringsperMPP Tracker 2/1+1 2/1+1 2/1+1 2/1+1 2/1+1 2/1+1 2/1+1 2/1+1 2/1+1 2/1+2
AC Output Side
Rated AC Output Active Power (kW) 3 4 5 6 7 8 9 10 12 15
Max.AC Output Apparent Power (kVA) 3.3 4.4 5.5 6.6 7.7 8.8 9.9 11 13.2 16.5
Rated AC Output Current (A) 4.6/4.4 6.1/5.8 7.6/7.3 9.1/8.7 10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8
Max. AC Output Current (A) 5/4.8 6.7/6.4 8.4/8 10/9.6 11.7/11.2 13.4/12.8 15/14.4 16.7/16 20/19.2 25/24
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.1% 98.1% 98.2% 98.2% 98.3% 98.3% 98.3% 98.3% 98.3% 98.5%
Euro Efficiency 97.5% 97.5% 97.6% 97.6% 97.8% 97.8% 97.8% 97.8% 97.8% 98%
MPPTEfficiency >99%
Equipment Protection
DC Reverse Polarity Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
Insulation Impedance Detection Yes
DC Component Monitoring Yes
Arc Fault Circuit Interrupter (AFCI) Optional
Anti-islanding Protection Yes
Residual Current Detection Yes
Surge Protection Level TYPE II(DC),TYPE II(AC)
DC Switch Yes
Interface
Communication Interface RS485/RS232
Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Noise (dB) <45
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 283×525×178 (Excluding Connectors and Brackets) 283×525×178 (Excluding Connectors and Brackets) 283×525×178 (Excluding Connectors and Brackets) 283×525×178 (Excluding Connectors and Brackets) 283×525×178 (Excluding Connectors and Brackets) 283×525×178 (Excluding Connectors and Brackets) 283×525×178 (Excluding Connectors and Brackets) 283×525×178 (Excluding Connectors and Brackets) 283×525×178 (Excluding Connectors and Brackets) 283×525×188
Weight (kg) 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 12
Warranty 5 Years
Type of Cooling Natural Cooling
Grid Regulation IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25, G98,G99,VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Rated 5–15 kW AC, this platform targets the Georgian B2B sweet spot: facilities paying ~0.35 ₾/kWh that consume heavily during daylight. Without batteries, every kWh generated offsets purchased energy at full tariff value when self-consumption is high—CAPEX stays focused on modules and AC infrastructure.

Dual MPPT inputs accept two independent array orientations or string lengths, reducing mismatch losses on complex rooftops. Three-phase output prevents single-phase neutral imbalance that plagues oversized residential installs. Export limitation parameters must match utility connection agreements; remote revenue metering may require CHINT DTSU 666 or Eastron SDM Modbus V2 when the billing CT is far from the inverter location.

Scaling is horizontal: multiple G06 units on segmented feeders, each with its own export cap. This is not parallel hybrid Master/Slave—each inverter is a standalone On-Grid channel. Transition to storage later implies hybrid retrofit or fleet replacement, not a firmware toggle.

Ideal for

  • Guesthouses, retail, and offices with three-phase service entrances
  • EPC teams needing dual MPPT on commercial tile or metal roofs
  • Owners prioritizing ROI speed over blackout resilience

Technical FAQ

Why three-phase On-Grid instead of hybrid?
When outages are tolerable and capital must minimize, On-Grid delivers the lowest installed cost per kWh offset. Hybrid adds 51.2 V or HV storage CAPEX and BMS complexity.
How do dual MPPTs help?
Two arrays (e.g., south + west) operate at independent MPP voltages, improving yield versus a single combined string.
Maximum AC output?
Model family spans up to 15 kW nameplate—confirm exact SKU label on the nameplate and size DC input within Deye's PV window for that variant.
EV charging on the same site?
On-Grid PV reduces grid draw for daytime charging; add a wallbox from our charger catalog. Load management may require CT clamps on the main feeder.
← Back to catalog: Inverters