How to Choose a Hybrid Inverter in Georgia
How to size a hybrid inverter for home or business in Georgia: kW class, under 10 ms UPS, 51.2 V LiFePO4 pairing with Deye.
From
2,999₾
Deye SUN-3.6K-SG03LP1-EU — compact single-phase 51.2 V hybrid at 3.6 kW for Georgia apartments and small homes: backup, net metering, and GEN AC coupling from Tbilisi stock.
| Parameter | SUN-3.6K-SG03LP1-EU |
|---|---|
| Energy-storage input data | |
| Battery Type | Lead-acid or Lithium-ion |
| Energy storage Voltage Range(V) | 40-60 |
| Max.Charging/Discharging Current(A) | 90 |
| Charging Strategy for Li-ion Energy storage | Self-adaption to BMS |
| Number of energy-storage inputs | 1 |
| PV String Input Data | |
| Max. PV Access Power (W) | 7200 |
| Max. PV Input Power(W) | 5760 |
| Max. PV Input Voltage(V) | 500 |
| Start-up Voltage(V) | 125 |
| MPPT Voltage Range(V) | 150-425 |
| Rated PV Input Voltage(V) | 370 |
| Max Operating PV Input Current(A) | 18+18 |
| Max Input Short-Circuit Current(A) | 27+27 |
| No.of MPP Trackers/No.of Strings MPP Tracker | 2/1+1 |
| AC Input/Output Data | |
| Rated AC Input/Output Active Power(W) | 3600 |
| Max. AC Input/Output Apparent Power (VA) | 3960 |
| Rated AC Input/Output Current(A) | 16.4/15.7 |
| Max. AC Input/Output Current(A) | 18/17.3* |
| Max. Continuous AC Passthrough (grid to load)(A) | 35 |
| Peak Power (off-grid)(W) | 2 times of rated power,10s |
| Rated Input/Output Voltage | 220V/230V 0.85Un-1.1Un L+N+PE |
| Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55,60/55-65 |
| Power Factor Adjustment Range | 0.8 leading to 0.8lagging |
| Total Current Harmonic Distortion THDi | <3% (of nominal power) |
| DC Injection Current | <0.5%ln |
| Efficiency | |
| Max. Efficiency | 97.6% |
| Euro Efficiency | 96.5% |
| MPPT Efficiency | >99% |
| Equipment Protection | |
| Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection |
| Surge Protection Level | TYPE II(DC),TYPE II(AC) |
| Interface | |
| LCD/LED Display | LCD |
| Communication Interface | WIFI, RS485, CAN |
| General Data | |
| Operating Temperature Range | -40 to+60℃,>45℃ Derating |
| Permissible Ambient Humidity | 0~100% |
| Permissible Altitude | 2000m |
| Noise(dB) | <45 |
| Ingress Protection(IP) Rating | IP 65 |
| Inverter Topology | Non-Isolated (solar), Isolated (energy storage) |
| Over Voltage Category | OVC II(DC),OVC III(AC) |
| Cabinet size(W*H*D)[mm] | 376*470*241.5(Excluding connectors and brackets) |
| Weight[kg] | 17.6 |
| Warranty | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
| Type Of Cooling | natural cooling |
| Grid Regulation | IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 |
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
Single-phase Georgian homes face asymmetric loads—HVAC on one leg, lighting on another. The SUN-3.6K-SG03LP1-EU supports backup transfer in milliseconds while remaining grid-tied for net metering when the utility allows. Energy storage expansion uses parallel 51.2 V modules (HECKMAN RLFP/WLFP, ECOBSS STORE) with CAN communication to the inverter BMS port.
The GEN port enables AC Coupling: retrofit an existing On-Grid string under hybrid supervision—critical when homeowners already invested in PV and now need blackout resilience after tariff hikes. Off-Grid logic can force the string inverter offline to protect energy storage SOC; On-Grid mode releases it for maximum harvest.
Metering defaults to CHINT DTSU 666 CT kits. Beyond 30 m to the billing point, specify Eastron SDM Modbus V2 with RS485 or PLC carriers. N-PE bonding relay behavior matches three-phase LP3 units—open on grid, closed on island—follow local grounding codes for separated neutral installations.
Official product documentation and datasheets.
Datasheet (PDF) PDFNearby power classes and matching LiFePO4 from Tbilisi stock — compare before you quote.
Engineering notes that help you size and choose this product.
How to size a hybrid inverter for home or business in Georgia: kW class, under 10 ms UPS, 51.2 V LiFePO4 pairing with Deye.
How inverters work: grid-tied vs hybrid. Which one you need for home or business in Georgia — request advice!
Why a 10 ms hybrid inverter UPS switchover protects servers and POS better than a classic UPS — topology and transfer timing.