Deye

Deye warnings & faults

W1–W32 and F1–F64 as shown on Deye hybrid displays / loggers. Partner lookup table — not a field repair manual.

← All brands

System names match the inverter / logger display (English). Descriptions are partner-facing. Firmware maps can differ by model family — treat F7 vs F07 and F8 vs F08 as alternate numbering on some lines.

W Warnings (W1–W32)

Code System name Description
W1 Grid Voltage Warning Grid voltage close to threshold limit
W2 FAN WARN Abnormal cooling fan operation
W3 Grid Phase Wrong Incorrect grid phase sequence
W4 Meter Comm Fail Energy meter communication failure
W5 Upgrade Error Warning Firmware upgrade error warning
W6 PV Voltage Warning PV input voltage close to limit
W7 PV Current Warning PV input current close to limit
W8 DC Bus Voltage Warning DC bus voltage close to limit
W9 AC Current Warning AC current close to threshold limit
W10 Internal Temp Warning High internal temperature warning
W11 Heatsink Temp Warning Elevated heatsink temperature
W12 Hardware Warning General hardware warning
W13 Firmware Version Warning Firmware version mismatch/conflict
W14 Grid Frequency Warning Grid frequency close to limit
W15 Grid Impedance Warning High grid impedance
W16 AC Voltage Unbalance Warning AC voltage phase unbalance
W17 AC Current Unbalance Warning AC current phase unbalance
W18 Power Derating Warning Inverter power derating active
W19 Reactive Power Control Warning Reactive power control active
W20 Export Limitation Warning Grid export limitation active
W21 Zero Export Warning Zero-export mode active
W22 DRM Control Warning DRM control active
W23 Remote Control Warning Inverter remotely controlled
W24 Parallel Sync Warning Parallel system synchronization warning
W25 Parallel Power Limit Warning Parallel system power limit warning
W26 Battery Voltage Warning Energy storage voltage close to limit
W27 Battery Temperature Warning Energy storage temperature close to limit
W28 BMS Data Abnormal Warning Abnormal BMS data received
W29 Communication Delay Warning Communication bus delay warning
W30 System Load Warning High system load warning
W31 Battery comm warn Energy storage communication warning
W32 Parallel comm warn Parallel communication warning

F Faults (F1–F64)

Code System name Description
F1 DC Inversed Fault Reverse DC (PV) polarity fault
F2 DC Insulation Failure Low DC insulation resistance
F3 GFDI Failure DC ground fault detection (GFDI) error
F4 GFDI Ground Failure Ground / GFDI fault
F5 EEPROM Read Failure EEPROM memory read failure
F6 EEPROM Write Failure EEPROM memory write failure
F7 DC/DC Softstart Fault DC/DC soft-start failure
F07 GFDI Fuse Blown Blown GFDI protection fuse
F8 GFDI Relay Failure GFDI protection relay fault
F08 GFDI Ground Touch Fault Improper ground contact / Touch fault
F9 IGBT Failure IGBT power module failure
F10 AuxPowerBoard Failure Auxiliary power supply board failure
F11 / F30 AC MainContactor Fault Main AC contactor failure
F12 / F31 AC SlaveContactor Fault Auxiliary AC contactor failure
F13 Grid Mode Changed Grid operational mode changed
F14 DC OverCurr Fault DC overcurrent fault
F15 SW AC OverCurr Fault Software AC overcurrent protection fault
F16 GFCI Leakage Fault AC leakage current exceeding threshold (GFCI)
F17 Tz PV OverCurr Fault PV instantaneous overcurrent fault
F18 HW AC OverCurr Fault Hardware-level AC overcurrent fault
F19 Tz Integ Fault Internal inverter integration/MCU fault
F20 Tz Dc OverCurr Fault Off-grid DC overcurrent fault
F21 DC Leakage Flow Fault DC leakage current detected
F22 Emergency Stop Fault System emergency shutdown triggered
F23 AC Leakage Current Fault Critical AC leakage current fault
F24 DC Insulation Impedance Fault Critically low DC insulation impedance
F25 DC Feedback Fault DC circuit feedback loop error
F26 DC Busbar Unbalanced Fault DC busbar voltage unbalance
F27 DC End Insulation Fault End-circuit DC insulation breakdown
F28 DCIOver M1/M2 Fault MPPT1 / MPPT2 overcurrent fault
F29 Parallel CANBus Fault Parallel CAN communication bus fault
F32 DC Channel High Fault Excessively high DC channel voltage
F33 AC OverCurr Fault General AC overcurrent fault
F34 AC Overload Fault AC power overload fault
F35 AC NoUtility Fault No grid utility voltage detected
F36 AC GridPhaseSeque Fault AC grid phase sequence failure
F37 AC Volt Unbalance Fault Critical AC voltage unbalance fault
F38 Parallel System Stop Parallel system emergency stop
F39 AC Over Current (1 cycle) Instantaneous 1-cycle AC overcurrent
F40 Internal DC Over Current Internal DC overcurrent fault
F41 Parallel System Stop Inverter cluster shutdown
F42 Parallel Version Fault Parallel units firmware mismatch
F43 AC VW OverVolt Fault Line V-W overvoltage fault
F44 AC VW UnderVolt Fault Line V-W undervoltage fault
F45 AC Line Over Voltage AC grid line overvoltage
F46 AC Line Under Voltage AC grid line undervoltage
F47 AC OverFreq Fault AC grid over-frequency fault
F48 AC UnderFreq Fault AC grid under-frequency fault
F49 Phase DC Component OC Phase 1 DC component overcurrent
F50 Phase DC Component OC Phase 2 DC component overcurrent
F51 Phase DC Component OC Phase 3 DC component overcurrent
F52 Grid Relay Fault Grid disconnect relay fault
F53 AC Relay Stuck Fault AC contactor/relay mechanically stuck
F54 AC Relay Self-Check Failure AC relay self-test failure
F55 DC Voltage Too High Dangerously high DC voltage
F56 DC Bus Voltage Too Low/High DC bus voltage out of operational range
F58 BMS Communication Fault Battery BMS communication failure
F62 DRM Function Stop Inverter shutdown via external DRM signal
F63 PV Overcurrent / Choke Fault PV filter choke / inductor overload
F64 High Heatsink Temperature Critical heatsink / IGBT over-temperature