What Runs on a 5 kW, 12 kW and 20 kW Inverter?
What can you run on a 5, 12 or 20 kW hybrid inverter at home in Georgia? Typical loads, pump start-up current, three-phase limits and battery runtime.
From
4,925₾
Next-gen single-phase LV hybrid — Deye SUN-5K-SG05LP1-EU-AM2-P: 5 kW, 2 MPPT, 40–60 V energy storage, AC couple and parallel-ready for Georgia apartments and small homes.
| Parameter | SUN-5K-SG05LP1-EU-AM2-P |
|---|---|
| Battery Input Data | |
| Battery Type | Lead-acid or LiFePO4 |
| Battery Voltage Range (V) | 40-60 |
| Max. Charging/Discharging Current (A) | 120 |
| Charging Strategy for Li-ion Battery | Self-adaption to BMS |
| Number of Battery Input | 1 |
| PV String Input Data | |
| Max. PV Access Power (W) | 10000 |
| Max. PV Input Power (W) | 8000 |
| Max. PV Input Voltage (V) | 500 |
| Start-up Voltage (V) | 125 |
| MPPT Voltage Range (V) | 150-425 |
| Rated PV Input Voltage (V) | 370 |
| Max. Operating PV Input Current (A) | 18+18 |
| Max. Input Short-Circuit Current (A) | 27+27 |
| No. of MPP Trackers / No. of Strings per MPP Tracker | 2/1+1 |
| AC Input/Output Data | |
| Rated AC Input/Output Active Power (W) | 5000 |
| Max. AC Input/Output Apparent Power (VA) | 5500 |
| Rated AC Input/Output Current (A) | 22.7/21.7 |
| Max. AC Input/Output Current (A) | 25/23.9 |
| Max. Continuous AC Passthrough (grid to load) (A) | 35 |
| Peak Power (off-grid) (W) | 2 times of rated power,10s |
| Power Factor Adjustment Range | 0.8 leading to 0.8lagging |
| Rated Input/Output Voltage | 220V/230V 0.85Un-1.1Un L+N+PE |
| Rated Input/Output Grid Frequency/Range (Hz) | 50/45-55,60/55-65 |
| Total Current Harmonic Distortion THDi | <3% (of nominal power) |
| DC Injection Current | <0.5%ln |
| Efficiency | |
| Max. Efficiency | 97.6% |
| Euro Efficiency | 96.5% |
| MPPT Efficiency | >99% |
| Equipment Protection | |
| Integrated Protections | DC Reverse Polarity Protection AC Output Overcurrent Protection Thermal Protection AC Output Overvoltage Protection AC Output Short Circuit Protection DC Component Monitoring Arc Fault Circuit Interrupter (AFCI) (optional) Anti-islanding Protection DC Switch Insulation Impedance Detection Residual Current Detection |
| Surge Protection Level | TYPE II(DC), TYPE II(AC) |
| Interface | |
| LCD/LED Display | LCD |
| Communication Interface | WIFI, RS485, CAN |
| General Data | |
| Operating Temperature Range (°C) | -40 to +60°C, >45°C Derating |
| Permissible Ambient Humidity | 0-100% |
| Permissible Altitude | 2000 m |
| Noise (dB) | <45 |
| Ingress Protection (IP) Rating | IP 65 |
| Inverter Topology | Non-Isolated (solar), Isolated (battery) |
| Over Voltage Category | OVC II(DC), OVC III(AC) |
| Cabinet Size (W×H×D mm) | 366×589.5×237 (Excluding Connectors and Brackets) |
| Weight (kg) | 26.8 |
| Type of Cooling | Intelligent Air Cooling |
| Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Key Features (datasheet) | |
| Max. Parallel Units (on-grid and off-grid) | 16 |
| Battery Charge/Discharge Time Periods | 6 |
Source: official Deye datasheet for SUN-3.6/5/6/7/7.6/8/10K-SG05LP1-EU-AM2-P; values are shown for this model.
The SG05LP1-EU-SM2-P platform is Deye’s next single-phase LV hybrid for Georgian homes that need more headroom than the compact SG03 series. Focus SKUs SUN-5K, SUN-6K and SUN-8K cover typical apartment and villa loads, while the same hardware family extends from 3.6 kW to 10 kW when a project needs it.
AC couple retrofit lets you keep an existing on-grid string under hybrid supervision. Six programmable energy storage windows and diesel GEN energy storage support help during multi-hour outages. Up to 16 inverters can run in parallel for larger single-phase estates or phased expansion.
Energy storage side stays 40–60 V with CAN BMS—pair HECKMAN RLFP/WLFP/MLFP or ECOBSS STORE modules within Deye’s approved list. Charge/discharge current scales with model: 120 A (5K), 135 A (6K), 190 A (8K), up to 210 A on the 10K.
Official product documentation and datasheets.
Datasheet (PDF) PDFField notes from Inversol Academy for the codes you are most likely to meet with this equipment.
Nearby power classes and matching LiFePO4 from Tbilisi stock — compare before you quote.
Engineering notes that help you size and choose this product.
What can you run on a 5, 12 or 20 kW hybrid inverter at home in Georgia? Typical loads, pump start-up current, three-phase limits and battery runtime.
Simple A + B + C formula: choose a hybrid inverter (5 or 8 kW), a LiFePO4 battery and charging speed for your home. Worked examples, peak shaving, UPS.