Net-Billing Georgia: Export 6 vs Import 35 Tetri — Why Storage Wins
Export ~6 tetri, import ~35. Hybrid + LiFePO4 for business — free Inversol consult.
From
4,200₾
Deye SUN-5K-SG03LP1-EU — single-phase 51.2 V hybrid at 5 kW for Georgia homes that need more headroom than 3.6 kW: backup, net metering, and GEN AC coupling.
| Parameter | SUN-5K-SG03LP1-EU |
|---|---|
| Battery Input Data | |
| Battery Type | Lead-acid or LiFePO4 |
| Battery Voltage Range (V) | 40-60 |
| Max. Charging/Discharging Current (A) | 120 |
| Charging Strategy for Li-ion Battery | Self-adaption to BMS |
| Number of Battery Input | 1 |
| PV String Input Data | |
| Max. PV Access Power (W) | 10000 |
| Max. PV Input Power (W) | 8000 |
| Max. PV Input Voltage (V) | 500 |
| Start-up Voltage (V) | 125 |
| MPPT Voltage Range (V) | 150-425 |
| Rated PV Input Voltage (V) | 370 |
| Max. Operating PV Input Current (A) | 18+18 |
| Max. Input Short-Circuit Current (A) | 27+27 |
| No. of MPP Trackers / No. of Strings per MPP Tracker | 2/1+1 |
| AC Input/Output Data | |
| Rated AC Input/Output Active Power (W) | 5000 |
| Max. AC Input/Output Apparent Power (VA) | 5500 |
| Rated AC Input/Output Current (A) | 22.8/21.8 |
| Max. AC Input/Output Current (A) | 25.0/24.0 |
| Max. Continuous AC Passthrough (grid to load) (A) | 35 |
| Peak Power (off-grid) (W) | 2 times of rated power,10s |
| Rated Input/Output Voltage | 220V/230V 0.85Un-1.1Un L+N+PE |
| Rated Input/Output Grid Frequency/Range (Hz) | 50/45-55,60/55-65 |
| Power Factor Adjustment Range | 0.8 leading to 0.8lagging |
| Total Current Harmonic Distortion THDi | <3% (of nominal power) |
| DC Injection Current | <0.5%ln |
| Efficiency | |
| Max. Efficiency | 97.6% |
| Euro Efficiency | 96.5% |
| MPPT Efficiency | >99% |
| Equipment Protection | |
| Integrated Protections | DC Reverse Polarity Protection AC Output Overcurrent Protection Thermal Protection AC Output Overvoltage Protection AC Output Short Circuit Protection DC Component Monitoring Arc Fault Circuit Interrupter (AFCI) (optional) Anti-islanding Protection DC Switch Insulation Impedance Detection Residual Current Detection |
| Surge Protection Level | TYPE II(DC), TYPE II(AC) |
| Interface | |
| LCD/LED Display | LCD |
| Communication Interface | WIFI, RS485, CAN |
| General Data | |
| Operating Temperature Range (°C) | -40 to+60°C, >45°C Derating |
| Permissible Ambient Humidity | 0-100% |
| Permissible Altitude | 2000 m |
| Noise (dB) | <45 |
| Ingress Protection (IP) Rating | IP 65 |
| Inverter Topology | Non-Isolated (solar), Isolated (battery) |
| Over Voltage Category | OVC II(DC), OVC III(AC) |
| Cabinet Size (W×H×D mm) | 376×470×241.5 (Excluding Connectors and Brackets) |
| Weight (kg) | 19 |
| Type of Cooling | natural cooling |
| Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
See the datasheet (PDF) for the full specification.
Single-phase Georgian homes face asymmetric loads—HVAC on one leg, lighting on another. The SUN-5K-SG03LP1-EU supports backup transfer in milliseconds while remaining grid-tied for net metering when the utility allows. Energy storage expansion uses parallel 51.2 V modules (HECKMAN RLFP/WLFP, ECOBSS STORE) with CAN communication to the inverter BMS port.
The GEN port enables AC Coupling: retrofit an existing On-Grid string under hybrid supervision—critical when homeowners already invested in PV and now need blackout resilience after tariff hikes. Off-Grid logic can force the string inverter offline to protect energy storage SOC; On-Grid mode releases it for maximum harvest.
Metering defaults to CHINT DTSU 666 CT kits. Beyond 30 m to the billing point, specify Eastron SDM Modbus V2 with RS485 or PLC carriers. N-PE bonding relay behavior matches three-phase LP3 units—open on grid, closed on island—follow local grounding codes for separated neutral installations.
Official product documentation and datasheets.
Datasheet (PDF) PDFField notes from Inversol Academy for the codes you are most likely to meet with this equipment.
Nearby power classes and matching LiFePO4 from Tbilisi stock — compare before you quote.
2999₾
3419₾
3299₾
2999₾
4925₾
6125₾
Engineering notes that help you size and choose this product.
Export ~6 tetri, import ~35. Hybrid + LiFePO4 for business — free Inversol consult.
Why a 10 ms hybrid inverter UPS switchover protects servers and POS better than a classic UPS — topology and transfer timing.