From
8,730₾
The Deye SUN-20K-SG01HP3-EU-AM2 is a High-Voltage (200–850+ V) commercial hybrid for 20 kW AC — the top AM2 frame before stepping into SUN-30K / SUN-50K class for larger B2B sites in Georgia.
| Parameter | SUN-20K-SG01HP3-EU-AM2 |
|---|---|
| Battery Input Data | |
| Battery Type | LiFePO4 |
| Battery Voltage Range (V) | 160-700 |
| Max. Charging/Discharging Current (A) | 37 |
| Charging Strategy for Li-ion Battery | Self-adaption to BMS |
| Number of Battery Input | 1 |
| PV String Input Data | |
| Max. PV Access Power (W) | 40000 |
| Max. PV Input Power (W) | 32000 |
| Max. PV Input Voltage (V) | 1000 |
| Start-up Voltage (V) | 180 |
| MPPT Voltage Range (V) | 150-850 |
| Rated PV Input Voltage (V) | 600 |
| Max. Operating PV Input Current (A) | 26+26 |
| Max. Input Short-Circuit Current (A) | 39+39 |
| No. of MPP Trackers / No. of Strings per MPP Tracker | 2/2+2 |
| AC Input/Output Data | |
| Rated AC Input/Output Active Power (W) | 20000 |
| Max. AC Input/Output Apparent Power (VA) | 22000 |
| Rated AC Input/Output Current (A) | 30.4/29.0 |
| Max. AC Input/Output Current (A) | 33.4/31.9 |
| Max. Continuous AC Passthrough (grid to load) (A) | 80 |
| Peak Power (off-grid) (W) | 1.5 times of rated power,10s |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Rated Input/Output Voltage | 220/380V,230/400V 0.85Un-1.1Un 3L+N+PE |
| Rated Input/Output Grid Frequency/Range (Hz) | 50/45-55, 60/55-65 |
| Total Current Harmonic Distortion THDi | <3% (of nominal power) |
| DC Injection Current | <0.5%ln |
| Efficiency | |
| Max. Efficiency | 97.6% |
| Euro Efficiency | 97.0% |
| MPPT Efficiency | >99% |
| Equipment Protection | |
| Integrated Protections | DC Reverse Polarity Protection AC Output Overcurrent Protection Thermal Protection AC Output Overvoltage Protection AC Output Short Circuit Protection DC Component Monitoring Arc Fault Circuit Interrupter (AFCI) (optional) Anti-islanding Protection DC Switch Insulation Impedance Detection Residual Current Detection |
| Surge Protection Level | TYPE II(DC), TYPE II(AC) |
| Interface | |
| LCD/LED Display | LCD |
| Communication Interface | WiFi, RS485, CAN |
| Monitor Mode | GPRS/WIFI/Bluetooth/4G |
| General Data | |
| Operating Temperature Range (°C) | -40 to +60°C, >45°C Derating |
| Permissible Ambient Humidity | 0-100% |
| Permissible Altitude | 2000 m |
| Noise (dB) | ≤ 55 |
| Ingress Protection (IP) Rating | IP 65 |
| Inverter Topology | Non-Isolated |
| Over Voltage Category | OVC II(DC), OVC III(AC) |
| Cabinet Size (W×H×D mm) | 408×638×237 (Excluding Connectors and Brackets) |
| Weight (kg) | 30.5 |
| Type of Cooling | Intelligent Air Cooling |
| Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Key Features (datasheet) | |
| Max. Parallel Units (on-grid and off-grid) | 10 |
| Battery Charge/Discharge Time Periods | 6 |
Source: official Deye datasheet for SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2; values are shown for this model.
Above roughly 20–30 kW of continuous power, 51.2 V architectures begin to punish installers: DC currents climb, mandating 35–50 mm² runs, heavy combiner boxes, and measurable I²R losses on every meter of cable. The 200–850+ V HV bus inverts that equation. A 25 kW charge/discharge profile on HV uses dramatically slimmer conductors and fewer parallel strings, directly cutting Balance of System (BOS) cost before a single kWh is stored.
Energy storage integration follows strict HV rules. Modules such as Heckman RHFP05100A (20–65 kWh scalable racks) or HECKMAN HV RHFP cabinets are wired in series—not parallel stacks of 51.2 V blocks. Every module must be pre-balanced to an identical State of Charge (SOC) before stringing; otherwise the Master BMS will lock out the string. CAN communication from the energy storage Master terminates at the inverter BMS port; grid-side metering typically uses CHINT DTSU 666 on short runs, or Eastron SDM Modbus V2 via RS485/PLC when the measurement point exceeds 30 m.
For Georgian B2B operators facing the 0.35 ₾/kWh tariff, this platform supports peak shaving, time-of-use arbitrage, and unbalanced three-phase loading across commercial feeders. Up to 10 inverters can be paralleled on the SG01HP3 architecture (Master/Slave CAN), scaling toward 250 kW while preserving a single energy storage communication hierarchy. AC Coupling via the GEN port remains available for retrofit sites upgrading legacy On-Grid PV without ripping existing string inverters.
Official product documentation and datasheets.
Datasheet (PDF) PDFField notes from Inversol Academy for the codes you are most likely to meet with this equipment.
Nearby power classes and matching LiFePO4 from Tbilisi stock — compare before you quote.
Engineering notes that help you size and choose this product.
Export ~6 tetri, import ~35. Hybrid + LiFePO4 for business — free Inversol consult.
Why a 10 ms hybrid inverter UPS switchover protects servers and POS better than a classic UPS — topology and transfer timing.
How to size a hybrid inverter for home or business in Georgia: kW class, under 10 ms UPS, 51.2 V LiFePO4 pairing with Deye.