5 Installation Mistakes That Void the Warranty on Your Solar System
Cable size, MC4, breakers, SPD and grounding, inverter settings, wiring: 5 installation errors that void a solar warranty, plus a pre-start checklist.
From
8,665₾
The Deye SUN-12K-SG05LP3-EU-SM2 is a low-voltage (51.2 V) three-phase hybrid inverter engineered for complex energy routing, featuring an internal N-PE bonding relay, <10 ms UPS transfer, and native support for extreme phase asymmetry.
| Parameter | SUN-12K-SG05LP3-EU-SM2 |
|---|---|
| Battery Input Data | |
| Battery Type | Lead-acid or LiFePO4 |
| Battery Voltage Range (V) | 40-60 |
| Max. Charging/Discharging Current (A) | 240 |
| Charging Strategy for Li-ion Battery | Self-adaption to BMS |
| Number of Battery Input | 1 |
| PV String Input Data | |
| Max. PV Access Power (W) | 24000 |
| Max. PV Input Power (W) | 19200 |
| Max. PV Input Voltage (V) | 800 |
| Start-up Voltage (V) | 160 |
| MPPT Voltage Range (V) | 200-650 |
| Rated PV Input Voltage (V) | 550 |
| Max. Operating PV Input Current (A) | 26+26 |
| Max. Input Short-Circuit Current (A) | 39+39 |
| No. of MPP Trackers / No. of Strings per MPP Tracker | 2/2+2 |
| AC Input/Output Data | |
| Rated AC Input/Output Active Power (W) | 12000 |
| Max. AC Input/Output Apparent Power (VA) | 13200 |
| Rated AC Input/Output Current (A) | 18.2/17.4 |
| Max. AC Input/Output Current (A) | 20/19.2 |
| Max. Continuous AC Passthrough (grid to load) (A) | 45 |
| Peak Power (off-grid) (W) | 2 times of rated power, 10s |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Rated Input/Output Voltage | 220/380V, 230/400V 0.85Un-1.1Un 3L+N+PE |
| Rated Input/Output Grid Frequency/Range (Hz) | 50/45-55, 60/55-65 |
| Total Current Harmonic Distortion THDi | <3% (of nominal power) |
| DC Injection Current | <0.5% In |
| Efficiency | |
| Max. Efficiency | 97.6% |
| Euro Efficiency | 97.0% |
| MPPT Efficiency | >99% |
| Equipment Protection | |
| Integrated Protections | DC Reverse Polarity Protection AC Output Overcurrent Protection Thermal Protection AC Output Overvoltage Protection AC Output Short Circuit Protection DC Component Monitoring Arc Fault Circuit Interrupter (AFCI) (optional) Anti-islanding Protection DC Switch Insulation Impedance Detection Residual Current Detection |
| Surge Protection Level | TYPE II(DC), TYPE II(AC) |
| Interface | |
| LCD/LED Display | LCD |
| Communication Interface | WIFI, RS485, CAN |
| General Data | |
| Operating Temperature Range (°C) | -40 to +60°C, >45°C Derating |
| Permissible Ambient Humidity | 0-100% |
| Permissible Altitude | 3000 m |
| Noise (dB) | ≤55 |
| Ingress Protection (IP) Rating | IP 65 |
| Inverter Topology | Non-Isolated (solar), Isolated (battery) |
| Over Voltage Category | OVC II(DC), OVC III(AC) |
| Cabinet Size (W×H×D mm) | 386×660×250 (Excluding Connectors and Brackets) |
| Weight (kg) | 35.2 |
| Type of Cooling | Intelligent Air Cooling |
| Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Key Features (datasheet) | |
| Max. Parallel Units (on-grid and off-grid) | 10 |
| Battery Charge/Discharge Time Periods | 6 |
Source: official Deye datasheet for SUN-3/4/5/6/8/10/12K-SG05LP3-EU-SM2; values are shown for this model.
The inverter supports heavily unbalanced phase loads, allowing up to 50% of its nominal power (6 kW) to be drawn on a single phase. For capacity expansion, up to 10 units can be connected in parallel using the Parallel A and Parallel B CAN interfaces in a daisy-chain topology. In this configuration, battery CAN communication (BMS port) is connected exclusively to the Master unit, while Modbus addresses are assigned sequentially to the Slaves.
The multifunctional GEN Port fundamentally alters system topology. When used for AC Coupling (Retrofit) alongside the Heckman Genswitch, the hybrid inverter actively controls the attached On-Grid string inverter. In Off-Grid mode, the Deye unit dictates the string inverter's shutdown to prevent energy storage overcharge, whereas in On-Grid mode, it allows the string inverter to operate without interference. For fire safety (P.POŻ compliance), killing power to the Load port requires physically cutting both the grid supply and the energy storage DC feed.
By default, the system uses the CHINT DTSU 666 meter. However, if the grid measurement point is more than 30 meters from the inverter, installation requires an external Smart Meter (e.g., Eastron SDM Modbus V2) utilizing RS485, Wi-Fi converters, or PLC (Power Line Communication) over existing phase wires. Grounding architecture depends on local regulations: the inverter features an internal relay that bonds the neutral and PE on the backup side during island mode, remaining open during grid-tied operation.
Official product documentation and datasheets.
Datasheet (PDF) PDFField notes from Inversol Academy for the codes you are most likely to meet with this equipment.
Nearby power classes and matching LiFePO4 from Tbilisi stock — compare before you quote.
Engineering notes that help you size and choose this product.
Cable size, MC4, breakers, SPD and grounding, inverter settings, wiring: 5 installation errors that void a solar warranty, plus a pre-start checklist.
How to tell if you have a single-phase or three-phase supply and which hybrid inverter you need: Deye and ECOBSS FLEX 3L. Comparison table and FAQ.
Turnkey 5 / 8 / 12 kW hybrid kits in Georgia from 11,314 ₾ VAT incl.: inverter, LiFePO4 storage, 9–20 Astorios panels. Build yours in the constructor.