Peak Shaving for Business in Tbilisi
Peak shaving for business in Tbilisi: cut Telasi/Energo-Pro demand peaks without a new feeder. Deye + LiFePO4 — request an audit!
From
32,290₾
The Deye SUN-80K-SG02HP3-EU-EM6 is a High-Voltage flagship hybrid for 80 kW AC — EM6 platform for large commercial / industrial clusters with multi-rack HV LiFePO₄ storage.
| Parameter | SUN-80K-SG02HP3-EU-EM6 |
|---|---|
| Energy-storage input data | |
| Battery Type | Lithium-ion |
| Energy storage Voltage Range (V) | 160-1000 |
| Max. Charging Current (A) | 80+80 |
| Max. Discharging Current (A) | 80+80 |
| Charging Strategy for Li-ion Energy storage | Self-adaption to BMS |
| Number of energy-storage inputs | 2 |
| PV String Input Data | |
| Max. PV Access Power (W) | 160000 |
| Max. PV Input Power (W) | 128000 |
| Max. PV Input Voltage (V) | 1000 |
| Start-up Voltage (V) | 180 |
| MPPT Voltage Range (V) | 150-850 |
| Rated PV Input Voltage (V) | 650 |
| Max. Operating PV Input Current (A) | 36+36+36+36+36+36 |
| Max. Input Short-Circuit Current (A) | 54+54+54+54+54+54 |
| No. of MPP Trackers/No. of Strings MPP Tracker | 6/2+2+2+2+2+2 |
| AC Input/Output Data | |
| Rated AC Input/Output Active Power (W) | 80000 |
| Max. AC Input/Output Apparent Power (VA) | 88000 |
| Rated AC Input/Output Current (A) | 121.3/115.9 |
| Max. AC Input/Output Current (A) | 133.4/127.6 |
| Max. Continuous AC Passthrough (grid to load) (A) | 200 |
| Peak Power (off-grid) (W) | 1.5 times of rated power, 10s |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Rated Input/Output Voltage/Range (V) | 220/380V, 230/400V 0.85Un-1.1Un |
| Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 |
| Grid Connection Form | 3L+N+PE |
| Total Current Harmonic Distortion THDi | <3% (of nominal power) |
| DC Injection Current | <0.5% In |
| Efficiency | |
| Max. Efficiency | 98.70% |
| Euro Efficiency | 98.1% |
| MPPT Efficiency | >99% |
| Equipment Protection | |
| Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection |
| Surge Protection Level | TYPE II(DC),TYPE II(AC) |
| Interface | |
| Communication Interface | RS485/RS232/CAN |
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) |
| General Data | |
| Operating Temperature Range (℃) | -40 to +60℃, >45℃ Derating |
| Permissible Ambient Humidity | 0-100% |
| Permissible Altitude | 3000m |
| Noise (dB) | ≤65 |
| Ingress Protection(IP) Rating | IP 65 |
| Inverter Topology | Non-Isolated |
| Over Voltage Category | OVC II(DC), OVC III(AC) |
| Cabinet Size (WxHxD mm) | 606×927×314 (Excluding Connectors and Brackets) |
| Weight (kg) | 105.0 |
| Type of Cooling | Intelligent Air Cooling |
| Warranty | 5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25, G99,VDE-AR-N 4105 |
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
At 80 kW continuous capability, a 51.2 V parallel energy storage farm would require multiple independent BMS networks, duplicated combiners, and copper buswork measured in kilograms per meter. The 200–850+ V platform collapses that complexity into a controlled series string: fewer conductors, lower I²R losses, and a single Master BMS handshake on CAN. For warehouses, food processing, logistics hubs, and light industry across Georgia, that directly reduces installed CAPEX before tariff arbitrage even begins.
Scaling follows the SG01HP3 Master/Slave playbook: up to 10 SUN-80K units can be paralleled—800 kW AC nameplate—while battery CAN remains on the designated Master inverter. HV modules (Heckman RHFP racks in OPEN RACK HP enclosures, or HECKMAN HV RHFP blocks) must be SOC-matched pre-commissioning; a single out-of-balance module can trip the entire string. AC-side integration supports full three-phase imbalance, GEN-port AC Coupling for legacy PV fleets, and external revenue-grade metering (CHINT DTSU 666 standard; Eastron SDM + PLC/RS485 when the grid tie point is remote).
Operationally, the 80K HP3 targets the 0.35 ₾/kWh B2B band with aggressive peak shaving, export limiting, and EMS-driven dispatch. EcoBSS PowerWallet scheduling can unify buy/sell/auto windows where stock Deye firmware would force manual 'Selling First' toggles. Because DC potentials approach 850 V, only licensed commercial teams should commission DC switchgear: insulated tools, HV-rated disconnects, visible isolation points, and documented emergency shutdown paths are non-negotiable—this is not a residential install scaled up.
Official product documentation and datasheets.
Datasheet (PDF) PDFNearby power classes and matching LiFePO4 from Tbilisi stock — compare before you quote.
Engineering notes that help you size and choose this product.
Peak shaving for business in Tbilisi: cut Telasi/Energo-Pro demand peaks without a new feeder. Deye + LiFePO4 — request an audit!
Export ~6 tetri, import ~35. Hybrid + LiFePO4 for business — free Inversol consult.
Why a 10 ms hybrid inverter UPS switchover protects servers and POS better than a classic UPS — topology and transfer timing.